2.1M LP2004TS Light Brown 20mm Acoustic Smoke & Intumescent Fire Seal
Twin Blade in Middle for FD30/60 doors
In stock
Delivery Information
| Delivery Time Frame | Delivery Information |
| Next Working Day By 1PM | When an order is placed by 3pm for next working day on certain items |
| Standard Delivery | Usually delivered in 2 to 4 working days |
| Delivery Charges | |
| UK Mainland | Prices start at £3.95 for very small items, £6.50 for small, £9.50 for medium and £20 for large/long items |
| Scottish Highlands & Islands, Northern Ireland & Ireland | Prices from £30, please see our delivery page for more info. |
-
Buy 50 +save 10%
-
Buy 100 +save 15%
-
Buy 150 +save 20%
Description
2.1M LP2004TS Light Brown 20mm Acoustic Smoke and Intumescent Fire Seal
Managing fire safety in commercial or residential buildings requires hardware that performs under extreme pressure. This 2.1 metre intumescent fire seal provides a versatile solution for door assemblies, combining fire integrity with essential acoustic and smoke control. It serves as a dependable barrier for single and double leaf doors, which helps you maintain strict building compliance across various public and private projects.
Installers choose this specific profile because it handles the demanding requirements of modern fire doors. Whether you are working on a new construction site or upgrading existing infrastructure, the seal bridges the gap between the door edge and the frame. It offers effective protection for fire ratings of 30 or 60 minutes, so your building stays safe while blocking out unwanted noise from corridors or adjacent rooms.
Why Fire Safety Compliance Matters for Your Building
Meeting UK fire safety standards means using components that are proven to perform when they are needed most. This seal offers the necessary certification to keep your building compliant with fire regulations. It acts as a invisible guardian within the door frame, providing peace of mind for building owners and occupiers alike. Using these seals is a straightforward way to uphold your duty of care without needing complex structural changes.
Why Choose the 2.1M LP2004TS Light Brown 20mm Acoustic Smoke & Intumescent Fire Seal?
This seal provides high-performance protection that integrates into your daily workflow without causing delays.
Active Fire Containment
The construction uses PVC encased sodium silicate material which reacts when exposed to intense heat. It expands to fill the door gap and stops fire from spreading, which gives occupants more time to exit the building. This chemical reaction is quick and predictable, forming a solid char that effectively blocks flames and smoke.
Effective Smoke and Noise Control
A twin blade configuration sits in the centre of the seal to manage air movement effectively. It blocks cold smoke leakage and provides sound insulation, which makes it ideal for private offices, hospitals, and busy residential flats. You will notice a significant improvement in the acoustic environment once these seals are fitted correctly.
Long-Term Operational Reliability
Each unit has been tested to survive 100,000 cycles of use. The elastomeric fins offer low frictional resistance so that doors open and close smoothly, which reduces wear on your door furniture and handles over time. This longevity saves you money on replacement hardware while keeping your fire door systems working as expected.
Understanding the Benefits of Intumescent Technology
Intumescent seals are a core component of modern fire door sets. They remain dormant during normal use but provide a critical barrier during a fire emergency. The sodium silicate material reacts precisely at the right temperature, meaning it only activates when a real risk is detected. By choosing this model, you are investing in a product that is designed for both safety and reliability over many years.
Engineering Quality and Daily Performance
Every aspect of the LP2004TS profile reflects the need for consistent performance in high-traffic environments.
Internal Mechanism and Force Distribution
The flexible twin blade interface bridges gaps between 3mm and 4mm with ease. This design stops smoke passing through but also keeps the door easy to operate, which prevents the frustration of stiff or dragging door leaves. You benefit from a profile that doesn't compromise on building accessibility or simple movement.
Because the seal is engineered to hold up under the daily stresses of heavy footfall, it keeps your fire doors compliant and functional for years. The material is lightweight yet strong, providing a steady grip on the door frame without requiring constant adjustments once the initial installation has been finished by the tradesperson.
Weather Resistance and Long-Term Finish
The PVC casing provides a durable housing for the active ingredients, keeping them protected from daily wear and tear. This construction ensures that the intumescent material remains effective even if the environment experiences high humidity or significant temperature fluctuations. Because the seal is easy to wipe clean, it remains in top condition.
We have carefully selected materials that resist brittleness and surface damage. This choice means the seal maintains its original shape and light brown colour, even in busy areas like communal stairwells or hotel corridors. You can expect a professional finish that blends into your interior design while doing its job.
Performance in High-Traffic Environments
Door hardware in commercial spaces needs to withstand constant use without failing. This seal is engineered to maintain its structural integrity regardless of how many times a door is opened or closed during the day. By using quality materials that resist deformation, the seal remains effective at keeping the gap between the door and frame properly filled. It provides a level of consistency that busy facilities managers require to keep doors operational and safe at all times.
Installation and Operational Workflow
Fitting these seals is a straightforward process when you follow standard maintenance protocols for fire door systems.
Prepare the Surface
Ensure the door groove is clean, dry and completely free from dust, oil or grease before you begin. Any contaminants will stop the adhesive from forming a secure bond with the door frame. Use a clean cloth or a small amount of mild cleaning agent to prep the area, then wait for it to dry.
Apply the Seal
Remove the backing from the heavy duty self-adhesive tape slowly to avoid stretching the material. Press the seal firmly into the groove, moving along the full length of the door or frame edge. Apply even pressure along the entire strip to make sure the adhesive creates a consistent and secure contact patch.
Check the Fit
Test the door operation to ensure the fins move without excessive resistance. Once applied, avoid any immediate heavy contact to allow the adhesive to set into its permanent position over the next few hours. A successful fit means the door closes softly and the seal engages the door leaf evenly.
Expert Installation and Care Tip
Never use oil or solvent based paints or primers near the installed seal. These chemicals can degrade the adhesive backing and compromise the integrity of the fire and smoke protection over time. Keep the area clean and free from decorating chemicals to maintain full performance.
Managing Ongoing Maintenance Requirements
Regular inspections form an essential part of your fire door maintenance schedule. You should periodically check that the seal remains firmly in place and that the blades are not damaged or missing. If you notice any signs of peeling or significant wear, it is time to replace the seal to maintain full fire protection. A few minutes spent checking your door hardware each quarter can prevent larger issues and help you stay fully compliant with UK safety laws.
Technical Specifications
| Feature | Rating / Standard | Practical Details |
|---|---|---|
| Fire Rating | FD30/60 | Suitable for 30 and 60 minute fire doors |
| Gap Capacity | 3mm to 4mm | Versatile for standard fire door leaf gaps |
| Product Length | 2.1 Metres | Standard length for most door edges |
| Durability | 100,000 cycles | Tested for long-term high traffic usage |
| Fire Standards | BS 476-22 & BS EN 1634-1 | Meets current UK fire safety regulations |
Longevity and Trade Reliability
Verified through testing by Certifire, BBA, and IFC, these seals offer genuine peace of mind for building managers. They provide long-term durability, which reduces your maintenance costs and ensures your fire safety certification remains valid for years.
Compatibility and Fitting Notes
Planning Your Door Upgrade Project
When upgrading multiple fire doors, consistency is key. Ensure you have enough 2.1 metre strips to cover all required gaps on every door leaf in your project. These seals are designed to be easily cut to size, so they will fit a range of standard door heights found in schools, hotels, or offices. If you need help calculating quantities for a larger refurbishment, our team is available to offer support and ensure you have everything you need for your site.
Specification
| Manufacturer | Lorient |
|---|---|
| Finish | Brown |
| Dimensions | 2100 x 20 x 4mm |