Adams Rite 7110-310-652 Electric Release Double Leaf Doors 12V Dc
In stock
Delivery Information
| Delivery Time Frame | Delivery Information |
| Next Working Day By 1PM | When an order is placed by 3pm for next working day on certain items |
| Standard Delivery | Usually delivered in 2 to 4 working days |
| Delivery Charges | |
| UK Mainland | Prices start at £3.95 for very small items, £6.50 for small, £9.50 for medium and £20 for large/long items |
| Scottish Highlands & Islands, Northern Ireland & Ireland | Prices from £30, please see our delivery page for more info. |
See our full range:
Description
Reliable Access Control for Commercial Double Doors
Double door sets in busy retail, commercial, and public environments face unique operational hurdles every single day. Balancing smooth daily foot traffic with stringent out-of-hours security requires hardware that releases instantly on command yet resists physical force when locked. On paired doors, misalignment and latch binding often lead to premature release wear, costly callouts, and unreliable locking. Facilities managers and project installers need a proven solution that installs neatly into the inactive leaf without compromising the clean architectural sightlines of metal entrance doors.
The Adams Rite 7110-310-652 Electric Release Double Leaf Doors 12V Dc provides the dependable engineering needed to address these exact access control challenges. Purpose-built for pairing with Adams Rite 4700 series deadlatches on double leaf hollow metal or aluminium installations, this electric strike replaces traditional fixed strike plates. Operating smoothly on continuous 12V DC power, it lets access control keypads, push buttons, or intercom systems release the door electrically while maintaining exceptional physical resistance against forced entry.
Key Operational Advantages
Direct Leaf Integration
Designed specifically for mounting directly into the inactive leaf of paired door configurations, this unit maintains clean sightlines. The flush faceplate sits flush against the frame edge, eliminating the need for bulky surface housings and preserving smooth door swing across high-traffic pedestrian entrances.
Low-Power 12V DC Operation
The internal 12V DC solenoid delivers quiet and instant actuation without drawing excessive current. It interfaces seamlessly with modern access control units, remote entry switches, and standby power supplies, making it an efficient choice for round-the-clock commercial facilities.
Hardened Durability
Featuring a durable zinc-aluminium alloy body paired with an architectural satin chrome finish, the unit resists physical wear and environmental corrosion. Its robust internal jaw mechanism tolerates repeated daily releases without suffering latch fatigue or mechanical drift.
Deadlatch Interoperability
Engineered to work seamlessly alongside industry-standard Adams Rite deadlatches, the release jaw accepts latch bolts securely. This provides reliable automatic locking every time the door swings shut, eliminating troublesome manual latching delays.
Installation and Operational Workflow
Stage 1 Preparation and Mortice Routing
Begin by aligning the strike position accurately against the active door latch bolt. Carefully prepare the cutout in the nose of the inactive leaf using the manufacturer template, ensuring clean edges and adequate internal depth for the strike body and wiring harness.
Stage 2 Electrical Wiring and Connection
Route the continuous 12V DC power cables through the inactive leaf via an appropriate door loop or concealed transfer hinge. Connect the leads to the terminal leads securely, verifying polarity and voltage stability at the release terminals before securing internal cables.
Stage 3 Faceplate Fitting and Alignment
Secure the strike body into the leaf using the supplied fixings. Fasten the faceplate flush against the door extrusion, taking care that the strike keeper sits directly in line with the projected latch bolt to eliminate operational friction and door bounce.
Stage 4 Operational Commissioning
Test the electric release across multiple continuous cycles with your access control equipment. Verify that the jaw releases smoothly without physical binding when side pressure is applied, and confirm that the active door latches firmly when returning to the closed position.
Technical Specifications
Product Application Guidelines
The Adams Rite 7110-310-652 Electric Release Double Leaf Doors 12V Dc is engineered primarily for commercial entrances featuring paired aluminium stiles or hollow steel doors. Typical environments include corporate offices, educational establishments, healthcare buildings, and managed retail spaces where double doors serve as key thoroughfares.
When fitting this release, pairing it with high-specification auxiliary hardware ensures peak performance. Installers should ensure that the active door features a correctly regulated door closer to bring the latch bolt back into positive engagement without violent slamming. For double doors that do not feature an overlapping rebate, the inactive leaf must remain firmly anchored using heavy-duty manual or automatic flush bolts to prevent movement during daily use.
Routine maintenance remains straightforward. Inspect the release jaw periodically for any accumulated dirt, grit, or debris that might impede smooth travel. A light application of dry silicone or PTFE spray will keep the pivot mechanism operating freely, ensuring that the assembly continues to provide dependable locking for years to come.